Commit Graph

26 Commits

Author SHA1 Message Date
Jon Evans d8be5f9ecf Don't allow pins with NC electrical type to join other nets
Fixes https://gitlab.com/kicad/code/kicad/-/issues/1826
2020-07-06 20:27:38 -04:00
Jon Evans b94e29e3b1 Persist ERC pin table in project settings
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2066

Also a partial fix for https://gitlab.com/kicad/code/kicad/-/issues/4577
2020-07-03 17:11:42 -04:00
Jeff Young 9f2be3714f Add unresolved variable testing for worksheet items. 2020-05-28 17:36:22 +01:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 9d6b987ecc Fixes to map pin-to-pin erorrs to new Warning/Error strucutre. 2020-05-01 18:49:42 +01:00
Jeff Young 41b5872f12 Add ERC & DRC checks for unresolved variables. 2020-03-30 14:15:59 +01:00
Jeff Young cee973dc04 Move ERC error reporting over to the new framework.
Fixes https://gitlab.com/kicad/code/kicad/issues/1989
2020-03-16 11:06:15 +00:00
Jeff Young 437f888c25 Schematic Setup dialog.
Includes:
- moving some of the project settings from the Preferences dialog
- ERC severites
- project-specific field-name templates

Fixes https://gitlab.com/kicad/code/kicad/issues/2145
2020-03-10 18:54:17 +00:00
Mark Roszko 11ff16be4e Switch to scoped enums 2019-12-20 14:11:39 +00:00
Jon Evans df600fc1a2 Fix a few ERC issues with no-connects and power pins
Fixes: lp:1824359
* https://bugs.launchpad.net/kicad/+bug/1824359
2019-04-11 21:24:39 -04:00
Jon Evans 83c7e7fc65 New connectivity algorithm and bus upgrades
Bus upgrades: core new connectivity code

Bus upgrades: eeschema integration and modifications

Bus upgrades: eeschema dialogs

Bus upgrades: netlist export

Bus upgrades: file format changes
2019-03-31 19:53:41 -04:00
Jeff Young ef3e045a9b Eradicate g_UserUnit from ERC/DRC.
(cherry picked from commit 98b8cd4)
2018-07-17 15:12:16 +01:00
Carsten Schoenert a11714b1a4 fix misspelled 'an other' -> 'another' 2018-04-08 13:24:37 -04:00
Jon Evans 0a81782b5d Add ERC check that a pin appears in only one net
Fixes: lp:1680638
* https://bugs.launchpad.net/kicad/+bug/1680638
2018-03-15 11:11:43 -04:00
Maciej Suminski 8e18aea11d New ERC rule verifying if all units of a component use the same footprint 2018-01-25 12:19:41 +01:00
jean-pierre charras fcdbb7484c fix Bug #152546 (Netlist not respecting case sensitivity for labels): the label matching is now case sensitive. To avoid issues with previous eeschema versions, add in ERC a dectection for "similar" labels (labels which differ only by a case sensitivity)
(this option can be disabled, and saved in project config)
2015-12-20 13:40:17 +01:00
unknown b0241bacf0 Eeschema ERC now catches errors of unmatched global labels. 2015-08-31 13:09:47 +02:00
jean-pierre charras d583b1ff98 Fix Bug #1462876 (Eeschema ERC NoConnect not reliable.) 2015-06-09 12:40:34 +02:00
maciej. 76aa0ba756 Fix compile errors when wx3.x is built with --enable-stl 2014-01-18 03:07:05 -06:00
jean-pierre charras f2e5da63e3 Eeschema: netlist generation: fix bad choice for the "best net name" when selecting a net name between labels connected to the same net.
Code cleanup and remove unused file.
2013-09-27 14:30:35 +02:00
Wayne Stambaugh d4fb921b43 Eeschema ERC improvements and other minor fixes.
* Move the hierarchical label connected test into the NETLIST_OBJECT class.
* ERC pin type strings can now be translated.
* Remove unused EDA_DRAW_PANEL attribute from all ERC test functions.
* Add get marker count method to SCH_SCREENS object.
* Redundant header removal.
* Lots of coding style policy fixes.
2011-10-07 10:41:30 -04:00
Wayne Stambaugh 4b853dedb4 Application name capitalization fixes.
* Correct all user strings and comments for the correct capitalization of
  application names according to JP.  They are KiCad, Pcbnew, CvPcb,
  Eeschema, and GerbView.
* Add a note the the user interface policy about the correct capitalization.
2011-09-30 14:15:37 -04:00
Wayne Stambaugh 73e38ce98c EESchema code refactoring and coding policy naming fixes.
* Move schematic wire and bus break code into schematic screen object.
* Move schematic test for dangling ends into schematic screen object.
* Remove left over debugging output in schematic screen object.
* Remove unused file eeschema/cleanup.cpp.
* Fix bug in schematic line object hit test algorithm.
* Fix a string concatenation compile error added in r2752.
* Rename class WinEDA_BasicFrame to EDA_BASE_FRAME.
* Rename class WinEDA_DrawFrame to EDA_DRAW_FRAME.
* Rename class WinEDA_DrawPanel to EDA_DRAW_PANEL.
2011-01-21 14:30:59 -05:00
Wayne Stambaugh 37ad67dfb1 EESchema file name and location house keeping. 2010-11-11 16:10:27 -05:00
stambaughw 1a4d23896e Begin translating comments to English and minor code clean up.
* Translate comments in source files beginning with A-E in eeschema.
* Spell check comments and strings and uncrusified all modified files.
2009-11-03 13:26:31 +00:00
charras 6d930edec3 work in progress about ERC and markers in eeschema 2009-07-07 17:50:02 +00:00